  Datasheet File OCR Text:
  low to medium power ac/dc power supplies 40-50 w ac/dc universal input switch mode power supplies 1 2 year warranty nlp40 series single, dual and triple output ? 4.25 x 2.5 x 1.15 inch package (1u applications) ? smallest industry package ? overvoltage and short circuit protection ? 40 w with free air convection ? en55022, en55011 conducted emission level b ? en61000-4-2, -3, -4, -5, -6 immunity compliant ? ul, vde and csa safety approvals ? a vailable rohs compliant the nlp40 series is a 40 w universal input ac-dc power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1u applications. this product is the smallest standard 40 w package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. the nlp40 provides 40 w of output power with free air convection cooling which can be boosted to 50 w with 20 cfm of air. standard features include overvoltage and short circuit protection. the series, with full international safety approval and the ce mark, meets conducted noise en55022 level b and has immunity compliance to en61000-4-2,-3,-4, -5, -6. the nlp40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, pos terminals, lcd projectors, cable modems and pabxs. this list is not exclusive as the generic feature set of the nlp40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications. all specifications are typical at nominal input, full load at 25 c unless otherwise stated general specifications hold-up time 120 vac 12 ms @ 40 w 230 vac 20 ms @ 40 w efficiency 75% typical isolation voltage input/output 3000 vac input/chassis 1500 vac switching frequency fixed 65 khz, 5 khz approvals and en60950, iec950, ul1950 standards (see note 8) vde0805, csa c22.2 no. 950 w eight 200 g (7.06 oz) mtbf mil-hdbk-217f 150,000 hours min. environmental specifications thermal performance operating ambient, 0 c to +70 c (see notes 6, 7, 9) (see derating curve) non-operating -40 c to +70 c 50 c to 70 c ambient, derate to convection cooled 50% load 0 c to 50 c, ambient, 40 w convection cooled 0 c to 50 c ambient, 50 w 20 cfm forced air peak (0 c to +50 c, 60 s) (see note 2) relative humidity non-condensing 5% to 95% rh altitude operating 10,000 feet max. non-operating 30,000 feet max. v ibration (see note 4) 5-500 hz 2.4 g rms peak shock per mil-std-810e 516.4 part iv output specifications t otal regulation main output 2.0% (line and load) auxiliary outputs 5.0% rise time at turn-on 1.0 s, max. t ransient response main output 5.0% max. dev., 25% step at 0.1 a/s 1 ms rec. to 1.0% t emperature coefficient 0.02%/c overvoltage protection main outputs 135%, 15% short circuit protection cyclic operation continuous minimum output current single 0 a multiple (see note 5) input specifications input voltage range universal input 90-264 vac (see note 9) 120-370 vdc input frequency range 47-440 hz input surge current 120 vac, cold start 15 a max. 230 vac, cold start 30 a max. safety ground 120 vac, 60 hz 0.2 ma leakage current 230 vac, 50 hz 0.4 ma input current 120 vac 1.4 a rms 230 vac 0.7 a rms input fuse ul/iec127 250 vac h 3.15 a emc characteristics (10) conducted emissions en55022, fcc part 15 level b radiated emissions en55022, fcc part 15 level a esd air en61000-4-2, level 3 perf. criteria 1 esd contact en61000-4-2, level 3 perf. criteria 1 surge en61000-4-5, level 3 perf. criteria 1 fast transients en61000-4-4, level 3 perf. criteria 1 radiated immunity en61000-4-3, level 3 perf. criteria 1 conducted immunity en61000-4-6, level 3 perf. criteria 1 specifications file name: nlp40.pdf rev (03): 08 nov 2005
for the most current data and application support visit www.artesyn.com/powergroup/products.htm nlp40 series single, dual and triple output low to medium power ac/dc power supplies 40-50 w ac/dc universal input switch mode power supplies 2 file name: nlp40.pdf rev (03): 08 nov 2005 output output current ripple (3) total model number (11,12) voltage max (1) peak (2) fan (1) regulation +3.3 v (i a )4 a5 a 4.5 a 50 mv 2.0% nlp40-76t366j (5) +12 v (i b )2 a3 a3 a 120 mv 5.0% C12 v (i c ) 0.2 a 1 a 0.5 a 120 mv 5.0% +5 v (i a )4 a5 a 4.5 a 50 mv 2.0% nlp40-7608j (5) +12 v (i b )2 a3 a3 a 120 mv 5.0% C12 v (i c ) 0.2 a 1 a 0.5 a 120 mv 5.0% +5 v (i a )4 a5 a 4.5 a 50 mv 2.0% nlp40-7610j (5) +15 v (i b ) 1.6 a 2 a 2 a 150 mv 5.0% C15 v (i c ) 0.2 a 1 a 0.5 a 150 mv 5.0% +12 v (i a ) 1.8 a 2.2 a 2.1 a 120 mv 2.0% nlp40-7627j (5) -12 v (i b ) 1.8 a 2.2 a 2.1 a 120 mv 5.0% +5 v (i a )4 a5 a 4.5 a 50 mv 2.0% nlp40-7629j (5) +12 v (i b )2 a3 a3 a 120 mv 5.0% 3.3 v (i a )8 a 10 a 9 a 50 mv 2.0% nlp40-76s3j 5 v 8 a 10 a 9 a 50 mv 2.0% nlp40-7605j 12 v 3.3 a 4.5 a 4 a 120 mv 2.0% nlp40-7612j 15 v 2.6 a 3.6 a 3.3 a 150 mv 2.0% nlp40-7615j 24 v 1.6 a 2.5 a 2 a 240 mv 2.0% nlp40-7624j 48 v 0.8 a 1.1 a 1 a 300 mv 2.0% nlp40-7617j notes 1 maximum output power is 40 w for natural convection cooling. with 20 cfm fan cooling, the maximum output power is 50 w. 2 peak output current lasting less than 60 seconds with duty cycle less than 5%. during peak loading, output voltage may exceed total reg. limits. 3 figure is peak-to-peak. output noise measurements are made across a 50 mhz bandwidth using a 12 inch twisted pair, terminated with a 47 f capacitor. 4 three orthogonal axes, random vibration 10 minutes for each axes, 2.4 g rms 5 hz to 500 hz. 5 for multiple output units (except -7627j, 76t366j) to maintain stated r egulation then: 0.25 i a / i b 5, for i b > 0.3 a 0.50 i a / i b 5, for i b < 0.3 a for maximum output current i(c) on triple output models, i.e. for i c = imax., i a min. 0.5 a and i a i b . for nlp40-7627j only, to maintain stated regulation then: 0.5 i a / i b 2. for nlp40-76t366j only, to maintain stated regulation then: 0.25 i a / i b 4. 6 for optimum reliability, no part of the heatsink should exceed 120 c, and no semiconductor case temperature should exceed 130 c. 7 caution: allow a minimum of 1 second after disconnecting line power when making thermal measurements. 8 this product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9 when the input voltage is <90 vac the operating range is 0 c to +40 c. 10 for system emi compliance, a ground choke may be required before connecting the ground wire to the chassis. it is recommended that this ground choke be placed as close as possible to the systems ac inlet to eliminate noise pick-up in the system. 11 the j suffix indicates that these parts are pb-free (rohs 6/6) compliant. tse rohs 5/6 (non pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 12 notice: some models do not support all options. please contact your local artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. derating curve output power (watts) 0 c 10 c 20 c 30 c 40 c 50 c 60 c 70 c 20w 40w 50w 20 cfm forced air cooling 25w natural convection cooling
datasheet ? artesyn technologies ? 2005 the information and specifications contained in this datasheet are believed to be correct at time of publication. however, arte syn technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. the information and specifications contained or described herein are subject to change in any manner at any time without notice. no rights under any patent accompany the sale of any such product(s) or information contained herein. for the most current data and application support visit www.artesyn.com/powergroup/products.htm nlp40 series single, dual and triple output low to medium power ac/dc power supplies 40-50 w ac/dc universal input switch mode power supplies 3 www.artesyn.com file name: nlp40.pdf rev (03): 08 nov 2005 international safety standard approvals vde0805/en60950/iec950 file 10401-3336-0093 licence no. 93662 ul1950 file no. e136005 csa c22.2 no. 950 file no. lr41062c c5 maximum component height 1.15 (29.21) tolerance: .xxx 0.005" .xx 0.02" all dimensions in inches (mm) 4.25 (107.95) 1 n j2 4.00 (101.60) 2.25 (57.15) 2.50 (63.50) f1 l j1 p1 mounting hole diameter 0.138 (3.50) typical 0.125 (3.175) t1 input and output connectors ac (j1) connector type molex 26-60-4030 type. dc (j2) connector type molex 26-60-4060 type. mating connectors ac (j1) mating connector type molex 09-50-3031 or equivalent with molex 08-50-0105 or equivalent crimp terminals. dc (j2) mating connector type molex 09-50-3061 with triurcon 6838 or equivalent crimp terminals. note: the input and output connectors are the same as those used on nfs40, nfn40, nal40 and nan40. input pin connections j1 pin 1 ac line pin 2 no pin pin 3 ac neutral p1 pin 1 safety ground output pin connections j2 single dual triple pin 1 +vout v (b) v (b) pin 2 +vout v (a) v (a) pin 3 +vout v (a) v (a) pin 4 return return return pin 5 return return return pin 6 return return v (c)


▲Up To Search▲   

 
Price & Availability of NLP40CJ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X